• Needleless Injection Site -Notes On The Use Of Needle-Free Infusion Connectors







    Method of operation:
    1. Strictly follow the aseptic operation regulations;
    2. Check the package, remove the positive pressure connector after opening, use a needleless connector syringe to extract 2-3ML of saline, connect it to the negative end of the positive pressure connector, and make the positive end of the connector vent upward;
    3. Remove the protective cap of the positive pressure connector and use its male end with the punctured indwelling needle;
    4. Pump back with a syringe to expel the air between the indwelling needle and the positive pressure connector;
    5. At this time, the infusion set is immediately connected, and the infusion set can be connected to the positive pressure connector immediately to perform the infusion.
    6. After the infusion, the positive pressure joint is injected with an appropriate amount of physiological saline to rinse the remaining liquid;
    7. The replacement of the positive pressure connector is generally based on the replacement period of the indwelling needle, and its disposal method can be handled according to the regulations of the hospitals in various regions.


    Precautions:
    1. When the infusion set is connected to the negative end of the positive pressure connector, the gas in the infusion tube must be drained to ensure that there is no gas in the infusion tube;
    2. When the syringe or infusion set is unplugged, do not clamp the connecting tube with hemostatic forceps or switch to avoid affecting the positive pressure;
    3. Remember not to pierce the negative end of the positive pressure connector with a needle.



    Yuhuan Shengjiu Mould Co., Ltd. provides safe, fast and simple needle-free injection site products that are safely used in medical Needleless Injection Site applications. Follow us to learn about related product information and technical information: https://www.medicalmould.net/product/



    Needleless Injection Site -Notes On The Use Of Needle-Free Infusion Connectors Method of operation: 1. Strictly follow the aseptic operation regulations; 2. Check the package, remove the positive pressure connector after opening, use a needleless connector syringe to extract 2-3ML of saline, connect it to the negative end of the positive pressure connector, and make the positive end of the connector vent upward; 3. Remove the protective cap of the positive pressure connector and use its male end with the punctured indwelling needle; 4. Pump back with a syringe to expel the air between the indwelling needle and the positive pressure connector; 5. At this time, the infusion set is immediately connected, and the infusion set can be connected to the positive pressure connector immediately to perform the infusion. 6. After the infusion, the positive pressure joint is injected with an appropriate amount of physiological saline to rinse the remaining liquid; 7. The replacement of the positive pressure connector is generally based on the replacement period of the indwelling needle, and its disposal method can be handled according to the regulations of the hospitals in various regions. Precautions: 1. When the infusion set is connected to the negative end of the positive pressure connector, the gas in the infusion tube must be drained to ensure that there is no gas in the infusion tube; 2. When the syringe or infusion set is unplugged, do not clamp the connecting tube with hemostatic forceps or switch to avoid affecting the positive pressure; 3. Remember not to pierce the negative end of the positive pressure connector with a needle. Yuhuan Shengjiu Mould Co., Ltd. provides safe, fast and simple needle-free injection site products that are safely used in medical Needleless Injection Site applications. Follow us to learn about related product information and technical information: https://www.medicalmould.net/product/
    WWW.MEDICALMOULD.NET
    Oxygen Mask Mould,Needleless Injection Site - Shengjiu Medical
    Shengjiu Medical has many years of experience in mold design and production of oxygen masks mould. We can provide higher engineering design and production efficiency. At the same time, we also provide safe, fast and simple needleless injection site products.
    0 Comments 0 Shares 832 Views 0 Reviews
  • Needleless Injection Site -Precautions For Use Of Medical Infusion Connectors







    1. The infusion connector can be marked with black marker or tape.
    2. The infusion connector on the intravenous indwelling needle does not need to mark the time, and the infusion connector on the CVC and PICC must be marked with the time.
    3. Replace the infusion connector at least every 7 days, such as blood transfusion or TPN every 24 hours; if there is blood in the infusion connector, the integrity is damaged, or the infusion connector is removed, the infusion connector should be replaced with a new one. .
    4. The infusion connector is not wrapped with gauze (Note: 1. When discharged with a tube; 2. The patient can be covered with gauze or gauze dressing when necessary.)


    Yuhuan Shengjiu Mould Co., Ltd. provides safe, fast and simple needle-free injection on-site products-(needle-free infusion connectors, etc.) for safe application in medical Needleless Injection Site applications. We have strict quality control throughout the production process of our products, making our products a safe choice for everyone. Is one of China's professional medical mould suppliers. Welcome to buy: https://www.medicalmould.net/product/





    Needleless Injection Site -Precautions For Use Of Medical Infusion Connectors 1. The infusion connector can be marked with black marker or tape. 2. The infusion connector on the intravenous indwelling needle does not need to mark the time, and the infusion connector on the CVC and PICC must be marked with the time. 3. Replace the infusion connector at least every 7 days, such as blood transfusion or TPN every 24 hours; if there is blood in the infusion connector, the integrity is damaged, or the infusion connector is removed, the infusion connector should be replaced with a new one. . 4. The infusion connector is not wrapped with gauze (Note: 1. When discharged with a tube; 2. The patient can be covered with gauze or gauze dressing when necessary.) Yuhuan Shengjiu Mould Co., Ltd. provides safe, fast and simple needle-free injection on-site products-(needle-free infusion connectors, etc.) for safe application in medical Needleless Injection Site applications. We have strict quality control throughout the production process of our products, making our products a safe choice for everyone. Is one of China's professional medical mould suppliers. Welcome to buy: https://www.medicalmould.net/product/
    0 Comments 0 Shares 566 Views 0 Reviews
  • Needleless Injection Site -Positive Pressure Needleless Connector Applications: What Tasks?



    The positive pressure connector is closed without any connection parts and remains sterile. The positive end of the connector can be connected to peripheral ports, central veins, indwelling needles, tee valves and other ports that require heparin caps. The negative end can connect and lock the syringe, infusion set, blood transfusion device, and complete the treatment tasks such as infusion, blood transfusion and blood drawing.


    1. When the syringe is pulled out, a positive pressure is generated and the liquid in the connecting tube is automatically advanced forward, which can prevent blood from flowing back into the indwelling needle and avoid the formation of blood clots;

    2. Needle-free infusion to avoid needle-point injury and reduce AIDS and hepatitis infections;

    3. Closed infusion, enough flow, equivalent to the flow of a 16G needle;

    4. Sealed valve device to reduce the potential danger of air intake;

    5. No need to puncture the heparin cap to prevent tiny particles from entering the infusion system;

    6. Reduce the infection and related complications of indwelling venous needles and catheters, and reduce the workload of nursing staff.


    Yuhuan Shengjiu Mould Co., Ltd. provides safe, fast and simple needle-free injection on-site products for safe application in medical Needleless Injection Site applications. We have strict quality control throughout the production process of our products, making our products a safe choice for everyone. Welcome to buy: https://www.medicalmould.net/product/



    Needleless Injection Site -Positive Pressure Needleless Connector Applications: What Tasks? The positive pressure connector is closed without any connection parts and remains sterile. The positive end of the connector can be connected to peripheral ports, central veins, indwelling needles, tee valves and other ports that require heparin caps. The negative end can connect and lock the syringe, infusion set, blood transfusion device, and complete the treatment tasks such as infusion, blood transfusion and blood drawing. 1. When the syringe is pulled out, a positive pressure is generated and the liquid in the connecting tube is automatically advanced forward, which can prevent blood from flowing back into the indwelling needle and avoid the formation of blood clots; 2. Needle-free infusion to avoid needle-point injury and reduce AIDS and hepatitis infections; 3. Closed infusion, enough flow, equivalent to the flow of a 16G needle; 4. Sealed valve device to reduce the potential danger of air intake; 5. No need to puncture the heparin cap to prevent tiny particles from entering the infusion system; 6. Reduce the infection and related complications of indwelling venous needles and catheters, and reduce the workload of nursing staff. Yuhuan Shengjiu Mould Co., Ltd. provides safe, fast and simple needle-free injection on-site products for safe application in medical Needleless Injection Site applications. We have strict quality control throughout the production process of our products, making our products a safe choice for everyone. Welcome to buy: https://www.medicalmould.net/product/
    0 Comments 0 Shares 555 Views 0 Reviews
  • Needleless Injection Site -Use Characteristics Of Pinless Connector





    When medical personnel (HCW) use needles in combination with IV treatment, they may suffer accidental needle stick injuries and may be infected with blood-borne pathogens such as hepatitis B or C virus or human immunodeficiency virus (HIV). In 1992, the United States Occupational Safety and Health Administration (OSHA) recommended that medical institutions use "engineering controls" to help protect HCWs from these pathogens. The use of such controls, including applicable NC systems, has become mandatory under the Acupuncture Safety and Prevention Act of 2001.

    The NC we see today comes from the industry's efforts to manufacture OSHA-compliant equipment. They are primarily designed for the safety of medical personnel. Ironically, certain over-the-counter drugs can unexpectedly increase patients' HA-BSI risk. In particular, in many studies, the two most widely used designs, the so-called "positive" and "negative" pressure Luer interface mechanical valves NC, are associated with an increased risk of HA-BSI. Generally speaking, these infection-related problems associated with Luer interface mechanical valves NC are related to their complex design. They have complex inner surfaces-including moving parts in some cases-which are difficult to properly disinfect and rinse. The inner surface may then be contaminated and become the basis for biofilm development and subsequent HA-BSI. Most NCs also require a specific conventional clamping sequence to disconnect, that is, clamp first, then disconnect, then disconnect and then clamp. If the clamping-disconnecting sequence is not performed correctly, the risk of insufficient disinfection and contamination increases the risk of HA-BSI.

    The "simple and better" general design principle applies to NC. Simpler NCs are unlikely to be associated with an increased risk of HA-BSI, as HCWs have less chance of incorrectly using them, and fewer opportunities for parts or other design elements to fail to function properly or fail. In addition, the inner and outer surfaces of simpler NCs are easier to completely disinfect and rinse.

    Yuhuan Shengjiu Mould Co., Ltd. also provides safe, fast and simple medical needleless connector products for Needleless Injection Site . Welcome to buy: https://www.medicalmould.net/product/

    Needleless Injection Site -Use Characteristics Of Pinless Connector When medical personnel (HCW) use needles in combination with IV treatment, they may suffer accidental needle stick injuries and may be infected with blood-borne pathogens such as hepatitis B or C virus or human immunodeficiency virus (HIV). In 1992, the United States Occupational Safety and Health Administration (OSHA) recommended that medical institutions use "engineering controls" to help protect HCWs from these pathogens. The use of such controls, including applicable NC systems, has become mandatory under the Acupuncture Safety and Prevention Act of 2001. The NC we see today comes from the industry's efforts to manufacture OSHA-compliant equipment. They are primarily designed for the safety of medical personnel. Ironically, certain over-the-counter drugs can unexpectedly increase patients' HA-BSI risk. In particular, in many studies, the two most widely used designs, the so-called "positive" and "negative" pressure Luer interface mechanical valves NC, are associated with an increased risk of HA-BSI. Generally speaking, these infection-related problems associated with Luer interface mechanical valves NC are related to their complex design. They have complex inner surfaces-including moving parts in some cases-which are difficult to properly disinfect and rinse. The inner surface may then be contaminated and become the basis for biofilm development and subsequent HA-BSI. Most NCs also require a specific conventional clamping sequence to disconnect, that is, clamp first, then disconnect, then disconnect and then clamp. If the clamping-disconnecting sequence is not performed correctly, the risk of insufficient disinfection and contamination increases the risk of HA-BSI. The "simple and better" general design principle applies to NC. Simpler NCs are unlikely to be associated with an increased risk of HA-BSI, as HCWs have less chance of incorrectly using them, and fewer opportunities for parts or other design elements to fail to function properly or fail. In addition, the inner and outer surfaces of simpler NCs are easier to completely disinfect and rinse. Yuhuan Shengjiu Mould Co., Ltd. also provides safe, fast and simple medical needleless connector products for Needleless Injection Site . Welcome to buy: https://www.medicalmould.net/product/
    WWW.MEDICALMOULD.NET
    Oxygen Mask Mould,Needleless Injection Site - Shengjiu Medical
    Shengjiu Medical has many years of experience in mold design and production of oxygen masks mould. We can provide higher engineering design and production efficiency. At the same time, we also provide safe, fast and simple needleless injection site products.
    0 Comments 0 Shares 823 Views 0 Reviews
Sponsored

Sakirabe

Create an account or log into Sakirabe. Connect with friends, family and other people you know. Share photos and videos, send messages and get updates